KTI Networks KSC-240 Guía de instalación Pagina 21

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 43
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 20
-21-
2.6 Power Failure Relay Output
The device provides a relay output to report power failure event to a
remote alarm monitoring system. The replay output is provided with two
contacts labeled PF+ and PF- in the terminal block interface.
Use the provided 2P terminal plug for signal wiring and plug into the PF+/
- contacts. The function is designed as :
Power is normal PF+ contact is shorted with PF- contact.
Power failure PF+ contact is disconnected with PF- contact.
Note: Be sure the voltage applied on PF+/- contacts is within the
specification of 30VDC/1A max. or 120VAC/0.5A max.
Vista de pagina 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 42 43

Comentarios a estos manuales

Sin comentarios