-7-
The following figure illustrates the front panels with different fiber connectors:
3.2 UTP Cable
When making a connection to another device using straight-through
UTP cable, make sure MDI-X to MDI connection rule is followed. The
following figure illustrates the pin assignments of a straight-through
UTP and a crossover UTP cable:
It is suggested to use straight-through UTP cables for all UTP connec-
tions. The maximum length and UTP cable categories used for the con-
nections to a 10BASE-T device and 100BASE-TX device are:
CONNECTED DEVICE UTP CABLE USED & MAXIMUM LENGTH
10BASE-T device Cat. 3, 4, 5 UTP (100 meters)
100BASE-TX device Cat. 5 UTP (100 meters)